Home / Materials / EOS PA 1101

EOS PA 1101

PA11PowderSLSEOS

Quick answer

EOS PA 1101 is a bio-based PA11 SLS powder derived from castor oil. Per the EOS data sheet it offers 50 MPa tensile strength (XY), 1650 MPa modulus and 30% elongation at break — its ductility and impact resistance, not stiffness, are the reason to choose it over PA12.

PA 1101 is EOS's polyamide 11 powder. PA11 is produced from castor oil, which makes it a bio-based polymer, and its molecular structure gives it a distinctly tougher character than PA12: EOS positions it for impact-resistant applications that must not splinter under load.

The headline number is elongation: 30% strain at break in X/Y (15% in Z) versus 18% (4% in Z) for PA 2200, at the same 1650 MPa modulus. That combination — PA12-like stiffness with much better ductility — is what clips, buckles and snap-fits need.

Properties (manufacturer datasheet)

PropertyValueTest method / note
Tensile strength (X/Y)50 MPaISO 527-1/-2; Z: 48 MPa
Tensile modulus1650 MPaISO 527-1/-2, all orientations
Elongation at break (X/Y)30%EOS "strain at break", ISO 527-1/-2; Z: 15%
Density1.03 g/cm³ISO 1183-1
Melting temperature201 °CISO 11357-1/-3

Values are reproduced from the manufacturer source(s) listed below, exactly as published. Properties the manufacturer does not publish are omitted rather than estimated — see the sourcing policy.

Processing notes

Typical applications

Frequently asked questions

Is PA 1101 bio-based?

Yes. PA11 is polymerised from a monomer derived from castor oil, and EOS markets PA 1101 on that basis. The polymer itself behaves like a technical nylon; "bio-based" describes the feedstock, not biodegradability.

PA 1101 or PA 2200?

Choose PA 1101 when the part must bend, snap or survive impact: 30% elongation versus 18%, and 15% versus 4% in Z. Choose PA 2200 for general-purpose parts where its balanced profile and lower melting point are convenient. The full comparison is in the PA11 vs PA12 guide.

Is PA 1101 stronger than PA 2200?

In tensile strength, marginally: 50 MPa vs 48 MPa (XY). In stiffness they are equal at 1650 MPa. The meaningful differences are ductility and impact behaviour, where PA11 leads clearly.

Sources

Last updated: November 2026